Section 19 in this part is the full quick-reference table. This card is the subset worth having in memory, plus the process around the day itself.
Key Terms
| Term | In one line |
|---|---|
| Clock management | Budgeting the session so you reach every requirement, not just the fun one |
| Requirements pass | The first 5 minutes: clarify scope, scale, and non-functionals before drawing anything |
| Stated assumption | “I’m assuming 99.9% — correct me if not”; converts a guess into a checkpoint |
| Two-way door | A reversible decision; say so out loud and move faster on it |
| Abstain / escalate path | What the system does when it isn’t confident — the question most candidates forget |
Numbers That Matter
| Figure | Value | Where it bites |
|---|---|---|
| Memory reference | ~100 ns | vs SSD random read ~100 µs — the 1000× step |
| Same-DC round trip | ~0.5 ms | Cross-AZ ~1–2 ms; cross-region ~30–60 ms; cross-continent ~100–150 ms |
| Redis GET | ~1 ms | Indexed SQL ~1–10 ms; complex join 50–500 ms+ |
| Vector search (HNSW) | ~5–50 ms | Embedding a chunk ~50–150 ms |
| LLM first token | ~200–500 ms small · ~500 ms–2 s frontier | Full non-streamed response 2–10 s |
| Availability | 99.9% ≈ 8.76 hrs/yr · 99.99% ≈ 52.6 min · 99.999% ≈ 5.26 min | Each extra nine ≈ an order of magnitude more effort |
| Per-query cost | ~$0.001–0.005 small · ~$0.01–0.03 frontier | Embeddings ~$0.0001 per 1K tokens |
| Arrive | 5–10 min early | Use the buffer to breathe, not to cram |
Decision Rules
- Know which tier your SLA actually needs. Every additional nine costs roughly 10× the engineering and operational effort — over-building toward five nines is a design smell, and saying so is a senior signal.
- Spend the first five minutes on requirements, not architecture. Scale, latency budget, consistency needs, compliance. The design that answers an unasked question scores zero.
- Manage the clock explicitly. Forty minutes perfecting one corner and no time for what the interviewer cared about is the most common architect-level failure. Say “I’ll come back to the caching detail — let me cover the write path first.”
- State assumptions rather than silently choosing. Every unstated assumption is either a correction you didn’t get, or a gap the interviewer marks against you.
- Rehearse the 4–5 STAR stories out loud, timed. Silent reading hides the pacing problems entirely.
- Have questions ready for them. Not logistics — the ones that reveal you’re evaluating the role too: how decisions get made, what the last architectural disagreement was, what would make this hire a failure in a year.
Say This Out Loud
“Before I draw anything — can I confirm the scale and the non-functionals? I’m assuming roughly this QPS at peak, a p95 latency budget in the low seconds, and that we need regional resilience but not multi-continent. If any of those are wrong the design changes materially, so I’d rather be corrected now.”
“That’s a two-way door — cheap to reverse — so I’d pick the simpler option now and revisit with real traffic data rather than spending our time here on it. The one-way door in this design is the data model, so that’s where I want to spend the analysis.”
“I want to be conscious of time. I’ve covered ingestion and the read path; I think the interesting risk is in consistency during a partition, so unless you’d rather go elsewhere, that’s where I’ll spend the next few minutes.”